Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Power Distribution Cables
Twisted pairs unshielded Type T/N signal cables
Construction
Conductor:
Stranded copper conductor tin or alloy coated where necessary for the application , conductor per ASTM or IEC
60228.
Separator tape: optional
Insulation:
Polyvinylchloride(PVC)/nylon according to IEEE 1580 2010 Type T/N,Type X, E, T, S, P, LSX and LSE as option.
Jacket:
Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N,
Type T, CP, CPE, L, P or TPO jacket as option (optional for Type P with HD thicknesses).
Armor: optional and shall be nonmagnetic
Sheath:
Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N,
Type T, CP, CPE, L, P or TPO sheath as option (optional except for tinned copper braid armoured cables).
Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO
jacket/sheath.
Table B.15—Typical dimensions and weights; twisted-pair signal cable 300 V; Type T/N cables, unshielded pairs
Number of pairs |
Conductor |
Unarmored |
Armored |
Armored and sheathed |
|||
Nom. |
Approx. |
Nom. dia. (in) |
Approx. weight (lb/1000 ft) |
Nom. dia. (in) | Approx. weight (lb/1000 ft) |
||
1 | 20 | 0.26 | 31 | 0.32 | 47 | 0.41 | 79 |
2 | 20 | 0.36 | 51 | 0.42 | 72 | 0.51 | 112 |
3 | 20 | 0.4 | 66 | 0.46 | 87 | 0.59 | 153 |
4 | 20 | 0.44 | 80 | 0.5 | 104 | 0.63 | 175 |
5 | 20 | 0.48 | 95 | 0.54 | 122 | 0.67 | 198 |
6 | 20 | 0.5 | 107 | 0.56 | 134 | 0.69 | 212 |
8 | 20 | 0.58 | 150 | 0.64 | 181 | 0.77 | 269 |
10 | 20 | 0.65 | 180 | 0.71 | 213 | 0.88 | 343 |
15 | 20 | 0.72 | 242 | 0.78 | 279 | 0.95 | 421 |
20 | 20 | 0.79 | 303 | 0.85 | 343 | 1.02 | 496 |
25 | 20 | 0.94 | 408 | 1 | 455 | 1.17 | 608 |
30 | 20 | 0.99 | 469 | 1.05 | 519 | 1.22 | 697 |
40 | 20 | 1.1 | 594 | 1.16 | 650 | 1.33 | 836 |
50 | 20 | 1.21 | 717 | 1.27 | 782 | 1.44 | 986 |
60 | 20 | 1.37 | 850 | 1.43 | 924 | 1.6 | 1146 |
1 | 18 | 0.28 | 38 | 0.34 | 54 | 0.44 | 92 |
2 | 18 | 0.39 | 66 | 0.45 | 87 | 0.58 | 152 |
3 | 18 | 0.44 | 88 | 0.5 | 112 | 0.63 | 183 |
4 | 18 | 0.48 | 109 | 0.54 | 136 | 0.67 | 212 |
5 | 18 | 0.56 | 148 | 0.62 | 179 | 0.75 | 265 |
6 | 18 | 0.58 | 167 | 0.64 | 198 | 0.77 | 286 |
8 | 18 | 0.64 | 208 | 0.7 | 241 | 0.83 | 337 |
10 | 18 | 0.72 | 252 | 0.78 | 289 | 0.95 | 431 |
15 | 18 | 0.8 | 347 | 0.86 | 387 | 1.03 | 542 |
20 | 18 | 0.91 | 477 | 0.97 | 524 | 1.14 | 697 |
25 | 18 | 1.04 | 583 | 1.1 | 636 | 1.27 | 830 |
30 | 18 | 1.09 | 677 | 1.15 | 733 | 1.32 | 935 |
40 | 18 | 1.22 | 868 | 1.28 | 933 | 1.45 | 1157 |
50 | 18 | 1.34 | 1057 | 1.4 | 1128 | 1.57 | 1371 |
60 | 18 | 1.52 | 1257 | 1.58 | 1337 | 1.81 | 1713 |
1 | 16 | 0.32 | 49 | 0.38 | 67 | 0.48 | 108 |
2 | 16 | 0.45 | 85 | 0.51 | 109 | 0.64 | 181 |
3 | 16 | 0.51 | 115 | 0.57 | 144 | 0.7 | 224 |
4 | 16 | 0.59 | 160 | 0.65 | 191 | 0.78 | 281 |
5 | 16 | 0.66 | 192 | 0.72 | 227 | 0.89 | 359 |
6 | 16 | 0.68 | 218 | 0.74 | 253 | 0.91 | 388 |
8 | 16 | 0.75 | 273 | 0.81 | 310 | 0.98 | 457 |
10 | 16 | 0.89 | 367 | 0.95 | 412 | 1.12 | 582 |
15 | 16 | 0.99 | 500 | 1.05 | 550 | 1.22 | 736 |
20 | 16 | 1.08 | 632 | 1.14 | 688 | 1.31 | 889 |
25 | 16 | 1.23 | 773 | 1.29 | 838 | 1.46 | 1063 |
30 | 16 | 1.3 | 901 | 1.36 | 969 | 1.53 | 1206 |
40 | 16 | 1.45 | 1160 | 1.51 | 1236 | 1.74 | 1596 |
50 | 16 | 1.59 | 1416 | 1.65 | 1499 | 1.88 | 1890 |
60 | 16 | 1.88 | 1797 | 1.94 | 1897 | 2.17 | 2353 |
NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.